| 1: | Summarium praecipuarum specificationum et systema cart type color doppler ultrasound |
| 1.1 | Trolley typus omnes digitalis color Doppler ultrasonic mainframe |
| 1.2 | Ultrasonic exercitum operating ratio: Fenestra operating ratio |
| 1.3 | ApplicationsAbdomen, obstetrica, gynaecologia, cor, ratio urinaria, organa parva, superficialia, vasa sanguinis, pediatrica, fœtus, musculoskeletales. |
| 1.4 | Probes:Specillum convexum, Specillum Tran-vaginum, Specillum Linearium, Specillum Micro-convexum, Specillum Cardiac, 4D Volumeprobe |
| 1.5 | Applications et famaAbdominis, OB, GYN, Cardiac, Urinariae, Partes minores, Superficiales, Vasculares, Pediatrics, Mensurae programmatum programmatum, nuntia programmata programmata, administratio fasciculorum programmatum, etc. |
| 1.6 | arteriae carotidis intima mensurae crassitudine (IMT' |
| 1.7 | Involucrum spectris automatic measurement |
| 1.8 | Plena digitalis transmissio et receptio trabi synthesizer |
| 1.9 | Color Doppler imaginatio. |
| 1.10 | Pulsus Doppler Imaging(PW) |
| 1.12 | Cohaeret Contra imaging(CCI) |
| 1.12 | Continua undam Doppler imaging(CW) |
| 1.13 | B/C/D real-time tria synchrona imaginatio |
| 1.14 | Virtus Doppler imaginatio-PDI) |
| 1.15 | Virtus directa Doppler imaginatio-DPDI) |
| 1.16 | M modus imaginandi |
| 1.17 | Anatomie M modus imaginandi |
| 1.18 | Color Doppler M modus imaginatio |
| 1.19 | Elastographia |
| 1.20 | TEXTUS Doppler imaginatio. |
| 1.21 | Conatus rate imaginatio (SRI) |
| 1.22 | TEXTUS harmonicae imaginationis. |
| 1.23 | Fusion harmonica imaginatio-FHI |
| 1.24 | Speckle Imaginem reducere SRI. |
| 1.25 | Panoramica imaginatio |
| 1.26 | Declinatio imaginatio |
| 1.27 | Trapezoidalis imaginatio |
| 1.28 | Adaptiva velocitas ipsum |
| 1.29 | Free manus 3D |
| 1.30 | Verus tempus 3D imaginatio 3D / 4D |
| 1.31 | DICOM3.0 |
| 1.32 | Monitor:≥21.5 inch,high definition ultrasonic display |
| 1.33 | ≥13.3 inch tactus screen |
| 1.34 | Clipboard physica: nisi imago in parte sinistra velum, quod directe transferri vel deleri potest. |
| 1.35 | Systema munus habet in upgrade-macula |
| 1.36 | Praesuppositio: pro diversis viscerum inspectione, conditiones inspectionis optimae imaginis, et operationis commensurationem reducens, et communitatem externam compositionis et compositionis constitutionem communiter adhibitam. |
| 1.37 | Probe interface: 4 |
| 1.38 | Sinica et Anglica Systema, Sinica et Anglica initus, ad libitum |
| 1.39 | Depth:≥360mm; |
| 1.40 | Fundo imaginatio |
| 2: | Probes |
| 2.1 Convexis probe | Fundamentalis Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz/3.5MHz/4.0MHz/4.6MHz/5.0MHz/5.4MHz,Harmonic Frequency4.0MHz/4.6MHz/5.0MHz, |
| 2.2 Linearibus probe | Fundamentalis Frequency:4.0MHz/4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz/10.0MHz/12.0MHz/13.3MHz,Harmonic Frequency8.0MHz/9.2MHz/10.0MHz, |
| 2.3 Recto specillo | Fundamentalis Frequency:4.0MHz/4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz/10.0MHz/12.0MHz/13.3MHz,Harmonic Frequency8.0MHz/9.2MHz/10.0MHz, |
| 2.4 Micro-convexum specillum | Fundamental Frequency3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz,Harmonic Frequency 6.0MHz/7.0MHz/8.0MHz, |
| 2.5 Cardiac probe | Fundamental Frequency:1.7MHz/1.9MHz/2.1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz,Harmonic Frequency3.4MHz/3.8MHz/4.2MHz, |
| 2.6 4D Codices probe | Fundamental Frequency2.0MHz/2.5MHz/3.0MHz/3.3MHz/3.7MHz/4.0MHz/5.0MHz/6.0MHz,Harmonic Frequency 4.0MHz/5.0MHz/6.0MHz, |
| 3: | 2D modus imaginandi |
| 3.1 | Lucrum 0-100,Step 2 adjustable |
| 3.2 | segmentum TGC:8 adjustable |
| 3.3 | Maximum focus punctum:≥7, quod per totum processum moveri potest. |
| 3.4 | Speckle reductionem:0-5,5 level |
| 3.5 | Spatium Synthesis:0-2,2 level(liner probe: 3 level, cardiac probe:0) |
| 3.6 | Dynamic:30-180,35 level,gradus 5 adjustable |
| 3.7 | Linea densitatis low、middle、high,3 level |
| 3.8 | Artus reciproci:0-4, 4 level |
| 3.9 | Vox reductionis:0-5,5 level |
| 3.10 | Ora Enhancement:0-5-5 level |
| 3.11 | Sana potentia:2-10, 9 level |
| 3.12 | grisea (0-67, 67) |
| 3.13 | Falsus color:0-67,67 level |
| 3.14 | Image style:Soft-Comparison,2 level |
|
| Tegumentum reale tempus habet vocis ostentationem, explorationem frequentiae, dynamicam range, pseudo-colorem, scalam griseam et alios 11 parametris adaptari possunt. |
| 4: | ColorDopplerImagingMode |
| 4.1 | Sanguinis lucrum:0-100,Step 2 |
| 4.2 | Parameter ostentationem:Velocity、variance |
| 4.3 | B-Restrain(B/W restrain):0-7, 7 level |
| 4.4 | Celeritas per:0-8, 8 level |
| 4.5 | Sampling number:6-24, 7 level |
| 4.6 | Sanguinis fluxus malle0-8, 8 level |
| 4.7 | Filtering1-6, 6 level |
| 4.8 | Sana potentia:2-6, 4 level |
| 4.9 | Vox reductionis:0-4, 4 level |
| 4.10 | Lenis treatment: 0-4, IV gradu |
| 4.11 | Artus reciproci 0-6, 6 level |
| 4.12 | Chromatography( Sanguinis graph0-37, 37 level |
| 4.13 | Linea densitatis, Minimum Medio High, III level |
| 4.14 | Frequency:4 campester adjustable |
| 4.15 | Velocity:Minimum 0.4K,Maximum 40.5Kconvexa probe:0.4K-4.3K-38.5Klinearis probe:0.4K-14.7K-39.0K trans-vaginale probe:0.4K-7.8K-39.7K Codices probe:0.4K-4.2K-34.8K Micro-convexus probe:0.4K-10.3K-40.5K cardiacum probe:0.4K-7.8K-39.7K |
|
| Ps. frequentia explorationis mutationes et crebrae valorem mutationes |
|
| PS:Frame rate mutationes cum velocitate |
| 5: | PulsefluctusDopplerPW) |
| 1 | Lucrum 0-100,Step 2 |
| 5.2 | Involucrum spectrum functionis: involucrum spectri temporis reale automatic, involucrum spectri manualis, et alii modi.Systema automatice analyses variasque notitias ostendit ut PSV, EDV, RI, PI, S/D, ACC, HR et alia huiusmodi.Potest excitare vel prope |
| 5.3 | Sample volume:0.5mm~30mm |
| 5.4 | Sanguis angel-75-75-gradus |
| 5.5 | Falsus color:0-67, 67 level |
| 5.6 | Dynamic range:20-40,4 level |
| 5.7 | Filter:0-9, 9 level |
| 5.8 | Lenis treatment:1-4, IV gradu |
| 5.9 | Sonus potentia:2-5, 4 level |
| 5.10 | Volume0-100, 10 level,Step 10 |
| 5.11 | Audio eliquare:0-4,4 level |
| 5.12 | Basi linea-1.0~1.0, |
| 5.13 | Gray map:0-67, 67 level |
| 5.14 | Scan velocitatis:100-500, 6 level |
| 5.15 | PRF:Minimum 0.5K,Maximum 87.5Kconvexa probe:0.5K-4.3K-63.3Klinearis probe:0.5K-14.5K-78.4K Trans-vaginale probe:0.5K-8.1K-78.4K Volumen probe:0.5K-4.2K-53.8K Micro-convexus probe:0.5K-10.3K-81.1K cardiacum probe:0.5K-4.3K-87.5K |
| 5.16 | Frequency:4 level |
|
| PS. Frequentia explorationis mutationes et mutationes valoris PRF |
|
| Ps. frequentia explorationis mutationes et crebrae valorem mutationes |
| 6: | Continuus undaDopplerCW) |
| 6.1 | Support probe: Cardiac probe |
| 6.2 | De revolutionibus B modus parametri est switchable |
| 6.3 | Lucrum 0-100,Step 2 |
| 6.4 | Sampling linea positio adjustable |
| 6.5 | PRF:0.9K~36.1K |
| 6.6 | Baseline:-1.0~1.0 |
| 6.7 | Sanguis angelus:-75~75 gradus |
| 6.8 | Grey map:0-67 |
| 6.9 | Scan velocitas 100-300 |
| 6.10 | Falsus color:0-67 |
| 6.11 | Dynamic range:20-40 |
| 6.12 | Filtering:0-9,9 level |
| 6.13 | Lenis treatment: 1-4 |
| 6.14 | Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz,4 level adjustable |
| 6.15 | Sana potentia-2-5 |
| 6.16 | Volume0-100 |
| 6.17 | Audio Filtering0-4 |
| 7: | M imaginatio anatomica |
| 7.1 | Subsidium probe:convexum specillum, specillum linearis, probe cardiac |
| 7.2 | De revolutionibus B modus parametri est switchable |
| 7.3 | Lucrum 0-100,Step 2 |
| 7.4 | M Sampling linea angelus adjustable |
| 7.5 | M Sampling linea longitudo est Novifacta |
| 7.6 | Sampling linea3, potest exponi vel occulti |
| 8: | Et effundatur sanguisM mode(MC) |
| 8.1 | De revolutionibus B modus parametri est switchable |
| 8.2 | Lucrum 0-100,Step2 |
| 8.3 | MC Sampling linea angelus adjustable |
| 8.4 | MC Sampling linea longitudo adjustable |
| 8.5 | Frequency:4 level |
| 8.6 | Sampling numerus:6-24 |
| 8.7 | Celeritas per:0-8, 8 level |
| 8.8 | Scan velocitatem 150-500 |
| 8.9 | Artus reciproci 0-6, 6 level |
| 8.10 | Filtering:1-6,6 level |
| 8.11 | Sanguis fluxus malle0-8,8 level |
| 8.12 | Lenis treatment: 0-4,4 campester |
| 8.13 | Map:0-37, 37 level |
| 9: | Elastographia |
| 9.1 | De revolutionibus B modus parametri est switchable |
| 9.2 | Lucrum 0-100,Step 2 |
| 9.3 | B / E. [Bupa real-time ostentationem in eodem screen |
| 9.4 | Specillum obsessio curvae ostentationem "Sursum / Est" |
| 9.5 | Pressura indicator talea ostensionem |
| 9.6 | Frequency:8-9 level,Adjustable;Secundum specillum ostentationis |
| 9.7 | Vox reductionis:0-2, 2 level |
| 9.8 | Artus reciproci 0-3, 3 level |
| 9.9 | Comparison:0-13, 13 level |
| 9.10 | Falsus color:0-3, 3 level |
| 9.11 | Nolite sustinere cardiac specillum |
| 10: | TEXTUSDopplerimaginatio. |
| 10.1 | Support specillum: cardiac probe |
| 10.2 | De revolutionibus B modus parametri est switchable |
| 10.3 | Lucrum 0-100,gradus 2 |
| 10.4 | ROI area Novifacta |
| 10.5 | Sampling numerus:6-24 |
| 10.6 | Velocitas:0.4K-8.0K |
| 10.7 | Artus correlation:0-6,6级 |
| 10.8 | TEXTUS malle0-7, 7 level |
| 10.9 | Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz |
| 10.10 | Suscipe color conversionis |
| 11: | Contendunt rate imaginatio |
| 11.1 | Support specillum: cardiac probe |
| 11.2 | De revolutionibus B modus parametri est switchable |
| 11.3 | ROI area Novifacta |
| 11.4 | Lucrum 0-100,Step 2 |
| 11.5 | Sampling number:6-24,6 level |
| 11.6 | Axial mediocris-1-4, 4 level |
| 11.7 | Velocitas:0.4K-8K |
| 11.8 | Artus reciproci 0-6, 6 level |
| 11.9 | TEXTUS Optimization:0-7,7 level |
| 12: | Panoramica imaginatio |
| 12.1 | Support probe:linear probe |
| 12.2 | Speckle Reduction:0-5, 5 level |
| 13: | Declinatio imaginatio |
| 13.1 | Support probe:linear probe |
| 13.2 | De revolutionibus B modus parametri est switchable |
| 13.3 | Declinatio angel:8 level |
| 13.4 | Speckle reductionis 0-5, 5 level |
| 13.5 | Dynamic rate:30-180,Step 5 |
| 13.6 | Linea densitatis humilis media alta III gradu |
| 13.7 | Frame Correlation:0-4, 4 level |
| 13.8 | Falsus color:0-67, 67 level |
| 13.9 | Image style:Soft-Comparison,2 level |
| 13.10 | Vox reductionis:0-5, 5 level |
| 13.11 | Ora Enhancement:0-5-5 level |
| 13.12 | Sana potentia:2-10,8 level |
| 13.13 | Gray map:0-67,67 level |
| 14: | Trapezoidalis imaginatio |
| 14.1 | Specillum firmamentum lineari specillo |
| 14.2 | De revolutionibus B modus parametri est switchable |
| 14.3 | Declinatio angel:8 level |
| 14.4 | Speckle reductionis 0-5, 5 level |
| 14.5 | Dynamic rate:30-180,Step 5 |
| 14.6 | Linea densitatis humilis media alta III gradu |
| 14.7 | Frame Correlation:0-4, 4 level |
| 14.8 | Falsus color:0-67, 67 level |
| 14.9 | Image style:Soft-Comparison,2 level |
| 14.10 | Vox reductionis:0-5, 5 level |
| 14.11 | Ora Enhancement:0-5-5 level |
| 14.12 | Sana potentia:2-10,8 level |
| 14.13 | Gray map:0-67, 67 level |
| 14.14 | Spatium Synthesis:0-2, 2 level |
| 15 | Freehand 3D imaginatio |
| 15.1 | Support specillo convexo, specillo lineari |
| 15.2 | Exemplar ostende: 4 imagines |
| 15.3 | Imago gyrationis X/Y/Z Axis |
| 15.4 | Multi- scalpere Visibilitas |
| 16 | Real-time 4D imaginatio |
| 16.1 | Support specillum: 4D volumen probe |
| 16.2 | De revolutionibus B modus parametri est switchable |
| 16.3 | Lucrum 0-100,Step 2 |
| 16.4 | Propono exemplar unum imaginem duo imagines quattuor imagines |
| 16.5 | Imago RotationX/Y/Z Axis |
| 16.6 | Multi- scalpere Visibilitas |
| 16.7 | Lux & umbra inversionem |
| 16.8 | Smooth:0-4, 4 level |
| 16.9 | Limen gradu:0-129, Gradus III |
| 16.10 | Perspicuus:1-509,Step 10 |
| 16.11 | Redde type:4 species,Surface、maximum、minimum、perspective |
| 17: | Fundo Imaging |
| 17.1 | Lucrum 0-100,Step 2 |
| 17.2 | segmentum TGC:8 adjustable |
| 17.3 | Maximum focus punctum:≥7, quod per totum processum moveri potest. |
| 17.4 | Speckle reductionem:0-5,5 level |
| 17.5 | Spatium Compone:0-2,2 level(lineari probe: 3 level,non support cardiac probe) |
| 17.6 | Dynamic range:30-180,35 level,Step 5 |
| 17.7 | Linea density:Low、Middle、High,3 level |
| 17.8 | Artus reciproci 0-4,4 level |
| 17.9 | Vox reductionis:0-5,5 level |
| 17.10 | Ora amplificationem 0-5 5 level |
| 17.11 | Sana potentia:2-10, 9 level |
| 17.12 | Gray map:0-67, 67 level |
| 17.13 | Falsus color:0-67,67 level |
| 17.14 | Image style:Soft-Comparison,2 level |
| 17.15 | Protractum gradum: Maximum LXXII graduConvexa probe:9 levelTrans-vaginal probe:72 level Micro-convexum probe:29 level Cardiac probe:40 level 4D Volume probe:17 level |
|
| PS:The screen real-time has display of voice power, Specable frequency, dynamic range, pseudo color, gray scale and other 11 parametris adaptari possunt. |
|
| PS: Cum specillum extensionis ad maximam pervenit, spatium summatim perstringitur 0 . |
| 18: | Munus mensurae et analysis: |
| 18.1 | Mensura generalis: Distantia, area, ellipsis, linea crucis, angulus, distantia ratio, volubilis, Volume (ellipsis), area ratio, diametri, angulus articularis. |
| 18.2 | Cardiac:Automatic spectrum involucrum、LV、Main arteria pulmonalis diametri 、RVEDd、RVEDs、LVM、LAV、HR、MVF、AO、AR、LVOT、TVF、Pulmonic valve、pulmonalis vena、RV、Doppler foetus cor sonus、LVET、LVM、 LVMI、AV |
| 18.3 | vascularis: carotidis intima (IMT), longitudo stenosis ratio, area stenosis ratio, IMT (murus posterior), IMT (murus anterior) |
| 18.4 | OB:Fetal exercitatione、AFI、TW、GS、CRl、OFD、HL、ulna、NT、Fibula、Nbonel、Radial、Tibia |
| 18.5 | GYN:uterus、cervix、corpus uteri/cervix uterus、left vena ovariana. |
| 18.6 | Urologia: prostate, residua urina sinistra renibus dextra sinistra suprarenalis dextra testis, left right testis, left vesiculae seminis ius vesiculae seminis |
| 18.7 | Vena diametri abdominis:liver、CHD、partalischolecyst、CBD、pancreas、spleen、 Interna diametri aortae abdominis |
| 18.8 | Thyroideum |
| 18.9 | Software package:Measurement package、Software sarcina、Medical records administratione software sarcina |
| 19: | Graphica et textus systematis procuratio |
| 19.1 | Hospes constructum in II rigidum SSD 120+1T),Start ieiunium et stabile |
| 19.2 | Movie playback:≥1200 tabulae |
| 19.3 | Internum documentorum fasciculi administrandi ratio: numerum, nomen, numerum, nomen ceptum, numerum ceptum notare et sic porro investigari et administrari potest, numerando, annotando numerum, nomen et cetera. |
| 19.4 | Genus fama est XVI " |
| 19.5 | One key fast report graphic and text management |
| 20: | Interface |
| 20.1 | USB interface:4 |
| 20.2 | HDMI interface: 1 |
| 20.3 | RJ-45 interface:1 |
| 20.4 | Grounding filum interface:1 |
| 20.5 | DVD RW:1 |
| 21: | Configurationis |
| 21.1 | Trolley type plenus digital color Doppler ultrasound diagnostica system |
| 21.2 | Probe: specillum convexum (vexillum), specillum linearis (libitum), specillum trans-vaginale (libitum), specillum cardiacum (libitum), 4D volumen specillum (libitum) |
| 21.3 | ≥13 velox adjusting spherae |
| 22: | Technologia, post-venditio muneris et aliis requisitis |
| 22.1 | Post acceptationem, warantum liberum est per duos annos. |
| 22.2 | Fabricator certificationem ISO13485 et EU CE certificationem habet. |